Display | Display | Touchscreen color display | Display resolution | up to 5 digits; selectable | Pressure units | mbar, bar, psi, Pa, kPa, hPa, MPa, mmHg, cmHg, inHg, mmH2O, mH2O, inH2O (4 °C), inH2O (20 °C), inH2O (60 °F), inHg (0 °C), inHg (60 °F), kg/cm², kp/cm², lbf/ft², kN/m², atm, Torr, micron, g/l (20 °C), kg/m³ (20 °C) as well as two user-defined units | Settings | Applications (Apps) | Measure, calibrate, logger, switch test | Measuring rate | 50 values/s | Menu languages | English, German, Spanish, French, Italian, Russian, Arabic, Chinese (settable) | Connections | External pressure sensor 1) | max. 2, compatible with model CPT7000 reference pressure sensors | External ambient module 1) | max. 1 ambient module 2) | External temperature probe 1) | max. 1 temperature probe 2) | Manual pressure generation 1) | -0.85 … +25 bar (-12.3 ... +360 psi) | Voltage supply | Power supply | internal Lithium-Ion rechargeable battery (typical charging time: < 5 h) | Battery life | typical 8 hours 3) | Permissible ambient conditions | Operating temperature | -20 ... +50 °C (-4 ... +122 °F) | Storage temperature | -20 ... +60 °C (-4 ... +140 °F) | Relative humidity | 0 ... 85 % r. h. (non-condensing) | Shock and vibration | 15 g per EN 60068-2-6 | Reference conditions per IEC 61298-1 | Atmospheric pressure | 860 hPa < P < 1,060 hPa (12.5 psi < P < 15.4 psi) | Ambient temperature | 18 °C < T < 28 °C, typ. 23 °C | Relative humidity | 35 % r. h. < T < 95 % r. h. , typ. 55 % r. h. | Position | Hand-held lying face-up | 1) Available as an option 2) Temperature probe and ambient module use the same connection. Cannot be used at the same time. 3) Continuous operation (without backlighting, WIKA-Wireless deactivated and the electrical module gives no voltage/current). |
Communication | Interface | WIKA-Wireless 4) | Case | Material | PC + ABS blend | Ingress protection | IP54 category 2 | Dimensions | See Data Sheet | Weight | approx. 1.9 kg (4.19 lbs.) without internal pump and reference sensor approx. 2.5 kg (5.51 lbs.) incl. internal pump and reference sensor | 4) Requires a PC with Bluetooth® 2.1 interface |
Internal sensor technology | Pressure 5) | Gauge pressure | bar | -1 ... +1 | -1 ... 5 | -1 ... 10 | -1 ... 20 | -1 ... 25 | psi | -14.5 ... +14.5 | -14.5 ... +70 | -14.5 ... +145 | -14.5 ... +300 | -14.5 ... +360 | Absolute pressure | bar abs. | 0 ... 1 | 0 ... 1.6 | 0 ... 6 | 0 ... 10 | 0 ... 20 | 0 ... 25 | psi abs. | 0 ... 14.5 | 0 ... 23 | 0 ... 87 | 0 ... 145 | 0 ... 290 | 0 ... 360 | Overpressure safety | 3 times | Accuracy of the measuring chain 6) | 0.025 % of span 7) | Resolution | 5 digits | Pressure connection | G 1/8 female thread (only with selected pneumatic unit) | Electrical safety: | Resistance to overvoltage | Yes | Short-circuit resistant | Yes | Reverse polarity protection | Yes | Voltage-resistant | Up to 60 V | Input impedance | Current measurement | 20 Ω | Voltage measurement | 1 MΩ | Current | Measuring range | 0 … 30 mA | Supply | 0 … 30 mA | Resolution | 1 μA | Accuracy | Measure: 0.01 % ±1 μA Supply: 0,01 % ±2 μA 8) | Voltage | Measuring range | DC 0 … 30 V | Supply | DC 24 V | Resolution | 1 mV | Accuracy | 0.01 % or reading ±1 mV | Barometric reference 1) 9) | Measuring range | 850 ... 1,100 mbar (12.3 ... 16 psi) | Accuracy | ±1 mbar | 1) Available as an option 5) The internal reference sensor is only available in combination with a pneumatic unit. 6) It is defined by the total measurement uncertainty, which is expressed with the coverage factor (k = 2) and includes the following factors: the intrinsic performance of the instrument, the measurement uncertainty of the reference instrument, long-term stability, influence of ambient conditions, drift and temperature effects over the compensated range during a periodic zero point adjustment. 7) Calibrated at 23 °C (74 °F) and in vertical mounting position. 8) In the event of interference caused by high-frequency electromagnetic fields in a frequency range of 200 ... 300 MHz, an increased deviation of up to 0.1 % is expected for the current output function. 9) The barometric reference can be used to switch pressure types, absolute <=> gauge. With gauge pressure sensors, the measuring range of the sensors must begin with -1 bar (-15 psi) in order to carry out a complete absolute pressure emulation. |
Power supply unit | Input voltage | AC 100 ... 240 V, 50 ... 60 Hz | Output voltage | DC 12 V | Nominal Output current | 2,500 mA | Permissible ambient conditions | Operating temperature | 0 ... 40 °C (32 ... +104 °F); up to 90 % r. h. (non-condensing) | Storage temperature | -40 ... +70 °C (-40 ... +158 °F) | Relative humidity | 20 ... 80 % r. h. (non-condensing) | | Temperature probe Pt100 1) | Measuring range | -50 ... +250 °C (-58 ... +482 °F) | Accuracy | 1/10 DIN, classe B ±0.1 °C | Probe length | 200 mm (7.87 in) | Probe diameter | 3 mm (0.12 in) | Cable length | 1 m (3.28 ft) | Connection to CPH7000 | max. 1 temperature probe 2) | User-defined RTD probe | Input of the coefficients of R0, A, B and C | | Ambient module 1) | Measuring range | Relative humidity | 0 ... 100 % r. h. | Temperature | -40 ... +125 °C (-40 ... +257 °F) | Accuracy | Relative humidity | ±1.8 % r. h. | Temperature | ±0.2 °C (0.36 °F) | Connection to CPH7000 | max. 1 ambient module 2) | | WIKA-Wireless 4) | Frequency range | 2,400 ... 2,500 MHz | HF output power | max. 2 dBm (+ 2 dBi) | Number of channels | 79 | Channel spacing | 1/2 MHz | Bandwidth | 80 MHz | Output power | 4 dBm / 10 mW | 1) Available as an option 2) Temperature probe and ambient module use the same connection. Cannot be used at the same time. 4) Requires a PC with Bluetooth® 2.1 interface |
Certificate | Calibration | Standard: 3.1 calibration certificate per EN 10204 Option: DKD/DAkkS calibration certificate | Recommended recalibration interval | 1 year (dependent on conditions of use) |
|