Ametek JOFRA RTC-250 Liquid Bath/Dry-Block Calibrator (28 to 250 C)

SKU
RTC250
Manufacturer:
JOFRA
JOFRA

Key Features:

  • High accuracy Down to ±0.04°C using the external reference sensor. 4-wire True-Ohm-Measurement technology is used
  • Excellent stability 0.01˚C
  • Wide temperature range
    RTC-158 from -22 to 155°C (-8 to 311°F)
    RTC-250 from 28 to 250°C (82 to 482°F)
  • Excellent temperature homogeneity Unique active dual-zone block ensures good temperature homogeneity in the calibration zone
  • DLC Dynamic Load Compensation Perfect temperature uniformity in the insert, even when calibrating large sensors or many sensors at a time. B and C models only
  • Temperature uniformity indicator Shows the degree of temperature uniformity in the insert when using the new DLC technology. B and C models only
  • New sensor basket In combination with the stirrer the newly developed sensor basket ensures virtually zero axial and radial gradients in the calibration zone
  • Intelligent reference sensors JOFRA reference sensors are supplied with intelligent plugs, holding the calibration data (coefficients) of the reference sensor. This is
    a truly plug’n’play calibration system
  • USB communication All RTC calibrators communicate via an easy-to-use USB port
  • EURAMET Best performing dry-block with regard to the EURAMET/cg-13/v.01 guideline for testing of dry-blocks
Product Options:
Special Price $17,235.54 Regular Price $17,935.00

Secured and trusted checkout with

Ametek JOFRA RTC-250: High accuracy, excellent stability 0.01C, wide temperature range. Range: 28 to 250°C

Advantages of the combined liquid bath/dry-block calibrator

  • • Automatic calibration of as many as 24 sensors at a time
  • • For customers, who only want to use liquid baths
  • • For calibration of odd sizes and shapes of sensors including sanitary sensors

            WET = no need for inserts, that fit the sensors
            DRY = more space for calibration of special sensors

  • • Industries who need to calibrate many sensors at a time or short sensors can benefit from the big well
  • • JOFRACAL software and RTC B-models can handle on-line calibration and documentation of multiple sensors calibrated simultaneously

 

 

FUNCTIONAL SPECIFICATIONS

Temperature range
RTC-158
@ ambient temp. 0°C/32°F.........-37 to 155°C/-35 to 311°F
@ ambient temp. 23°C/73°F.........-22 to 155°C/-8 to 311°F
@ ambient temp. 40°C/104°F........ -9 to 155°C/16 to 311°F
RTC-250
@ ambient temp. 0°C/32°F..............5 to 250°C/41 to 482°F
@ ambient temp. 23°C/73°F..........28 to 250°C/82 to 482°F
@ ambient temp. 40°C/104°F......45 to 250°C/113 to 482°F
Accuracy (model B & C) with external STS ref. sensor
RTC-158 B & C.......................................... ±0.04°C/±0.07°F
RTC-250 B & C.......................................... ±0.07°C/±0.13°F
12-month period. Relative to reference standard. Specs by use of
the external STS-200 reference sensor. Excl. sensor drift.
Accuracy with internal reference sensor
RTC-158 A, B & C...................................... ±0.18°C/±0.32°F
RTC-250 A, B & C...................................... ±0.28°C/±0.50°F
Stability
RTC-158................................................... ±0.01°C/±0.018°F
RTC-250................................................... ±0.02°C/±0.036°F
Measured after the stability indicator has been on for 15 minutes.
Measuring time is 30 minutes.
Radial homogeneity (difference between holes)
RTC-158 @ -22°C/-8°F, Block........................0.03°C/0.05°F
RTC-158 @ 155°C/311°F, Block.....................0.05°C/0.09°F
RTC-158 @ range, Bath................................0.015°C/0.03°F
RTC-250 @ range, Block.................................0.05°C/0.09°F
RTC-250 @ range, Bath................................0.015°C/0.03°F
Resolution (user-selectable)
All temperatures .......................1° or 0.1° or 0.01° or 0.001˚
Heating time
RTC-158 -22 to 23°C/-8 to 73°F.................... 9 minutes
23 to 100°C/73 to 212°F............... 23 minutes
100 to 155°C/212 to 311°F........... 28 minutes
RTC-250 28 to 100°C/82 to 212°F................. 3 minutes
50 to 100°C/122 to 212°F............... 2 minutes
100 to 250°C/212 to 482°F............. 9 minutes
Cooling time
RTC-158 155 to 100°C/311 to 212°F............. 9 minutes
100 to 23°C/212 to 73°F............... 24 minutes
23 to 0°C/73 to 32°F..................... 15 minutes
0 to -15°C/32 to 5°F..................... 21 minutes
RTC-250 250 to 100°C/482 to 212°F........... 27 minutes
100 to 50°C/212 to 122°F............. 27 minutes
50 to 28°C/122 to 82°F................. 28 minutes
Time to stability (approx.)
RTC-158.............................................................. 15 minutes
RTC-250.............................................................. 15 minutes
Immersion depth
RTC-158/250 incl. insulation plug................. 180 mm/7.1 in
RTC-158/250 bath version............................ 150 mm/5.9 in

PHYSICAL SPECIFICATIONS
Weight and instrument size (L x W x H)
RTC-158........................................................... 11 kg/24.3 lb
RTC-250.........................................................9.9 kg/ 21.8 lb
RTC-158/250..... 366 x 171 x 363 mm / 14.4 x 6.7 x 14.3 in
Shipping (without carrying case)
RTC-158........................................................... 17 kg/37.5 lb
RTC-250........................................................... 16 kg/35.3 lb
Size.......................580 x 250 x 500 mm/22.8 x 9.8 x 19.7 in
Shipping (including optional carrying case)
RTC-158........................................................... 28 kg/61.7 lb
RTC-250........................................................... 27 kg/59.6 lb
Size.....................550 x 430 x 660 mm/21.7 x 16.9 x 26.0 in
INSERTS
Insert dimensions
RTC-158/250 outer diameter........................63.5 mm/2.5 in
RTC-158/250 length.......................................160 mm/6.3 in
Weight of non-drilled insert (approx.)
RTC-158/250................................................. 1200 g/42.3 oz
Alloy
RTC-158/250................................... Special aluminium alloy
Use of other inserts may reduce performance of the calibrator.
To get the best results out of the calibrator, the
insert dimensions, tolerance and material is critical. We
highly advise using JOFRA inserts, as they guarantee
trouble free operation.