Intempco M03 Industrial Temperature Sensor with Extension Cable
|
Manufacturer: Intempco
Part Number: M03
Product Options
* denotes required field
Probe Angle Selection*
Calibrated Temperature Range Selection*
Output Selection*
Probe Dia. "D", Mat'l & Length "L" Selection*
Fitting Type Selection*
Extension Cable & Length Selection*
|
Intempco M03 Industrial Temperature Sensor with Extension Cable
The MIST M03 temperature transducer, with its simple construction, is the base model in our line of MIST Industrial Series Temperature Sensors™. It replaces commonly used temperature sensors in a variety of applications where 4-20mA is required.
Features:
-
Field Programming
-
Superior Accuracy
-
Compact Size
-
Robust and Long Lasting
-
Best Value
-
Easy Installation
-
Traceable Calibration
Applications:
-
Industrial design, hermetically sealed, with extension cable
-
Stainless steel construction
-
Connection: NPT, all std. sizes
Most common selections shown above, call (732) 632-6400 for additional options.
Specifications:
|
Electrical Properties
|
|
Input:
|
RTD, type Pt100
|
|
Sensor Temperature Ranges:
|
See Box 1 code for standard ranges. Field re-selectable between -200°C to 600°C or -50°C to 200°C, depending on model
|
|
Output:
|
4-20mA loop powered, linear to temperature
|
|
Power Supply:
|
12-32VDC, polarity protected
|
|
Suppply Effect:
|
0.001 %/V
|
|
Accuracy:
|
±(0.25°C + 0.40% of span) with one point calibration¹
±(0.10°C + 0.10% of calibrated span with two-point calibration²
|
|
Maximum Loop Resistance:
|
[(Vsupply -7) * 40] ohms
|
|
Sensor Open Circuit:
|
Upscale 24mA or Downscale 2.5mA
|
|
Warmup:
|
30 Seconds
|
|
RFI Effect:
|
1% or less typical
|
|
Isolation:
|
500 VDC Input/Output
|
|
Temp. Effects:
|
±0.001% of Span/°C
|
|
Long Term Drift:
|
<0.1% FS/Year
|
|
Mechanical Properties
|
|
Probe and Housing Material:
|
Stainless steel 316, welded to probe
|
|
Cable Material:
|
PVC, Teflon or stainless steel armor over Teflon
|
|
Protection:
|
NEMA 6P (IP67), hermetically sealed
|
|
Storage Temp. Range:
|
-40°C to 80°C
|
|
Operating Temp. Range:
|
-40°C to 80°C (housing only)
|
|
Maximum Operating Pressure:
|
1500 PSIG Max (probe only)
500 PSIG (Tri-clamp)
|
|
Standard Surface Finish:
|
Polished to #4 finish per 3-A standard 74-02, 32 micro-inches max.
|
|
Pharmaceutical Surface Finish:
|
Polished to mirror finish and passivated, 10 micro-inches typical
|
¹Max. error on complete span. Error at calibration point <0.1% of Span.
²Max. error on complete calibration span. Error at calibration points <0.1% of Span.
M03: